vector.com|Contact
Search tips

apple banana
Find rows that contain at least one of the two words.

+apple +juice
Find rows that contain both words.

+apple macintosh
Find rows that contain the word 'apple', but rank rows higher if they also contain 'macintosh'.

+apple -macintosh
Find rows that contain the word 'apple' but not 'macintosh'.

+apple ~macintosh
Find rows that contain the word 'apple', but if the row also contains the word 'macintosh', rate it lower than if row does not. This is "softer" than a search for '+apple -macintosh', for which the presence of 'macintosh' causes the row not to be returned at all.

+apple +(>turnover >strudel)
Find rows that contain the words 'apple' and 'turnover', or 'apple' and 'strudel' (in any order), but rank 'apple turnover' higher than 'apple strudel'.

apple*
Find rows that contain words such as 'apple', 'apples', 'applesauce', or 'applet'.

"some words"
Find rows that contain the exact phrase 'some words' (for example, rows that contain 'some words of wisdom' but not "some noise words").

By continuing to use this site you agree to the use of cookies. For more information and to find out how to change this click here. Accept Cookies
Please enable cookies in your browser for this website.
Search:
Advanced search
Data Analysis
document
2020-05-18 Converters Cannot Be Selected any More
Issue: Under WIN 7 converters can not be selected anymore. Solution: Please check if vector.ini is read-protected and disable the read protection. The location of the used “vector.ini” can be determined under Backstage Tab | Help | About | More Info… Please check if chapter...
2020-05-18 rating Views: 1392
document
2019-02-27 FFT-Analysis with CANape
Support Note: This Support Note describes the FFT-Analysis with CANape. Note: Please note, that this Support Note is only valid for CANape up to version 16. The described functions are not available in CANape 17 and higher in this way.
2019-02-27 rating Views: 1374
document
2020-05-18 Signal Used in Configuration
Question: Is a signal already used in the configuration? Answer: To find out, if a signal is already used in one of the configuration windows, there are two possibilities: In the Symbol Explorer you will find all signals under measurement list or calibration object. To find in, if a...
2020-05-18 rating Views: 1030
document
2019-07-15 User Defined Comments for DataMining Analysis
Question: How to create user defined comments for every hit during the DataMining run in CANape? Answer: If you are using functions during a DataMining analysis you have the possibility to create your own comments for every DataMining hit in the result window of the analysis. This can be used...
2019-07-15 rating Views: 999
document
2020-05-18 Signal Identification in Graphical Window
Question: How to identify a signal in the Graphics window? Answer: In single signal mode there are two possibilities to display the signals: Display only the selected signals, unselected signals are not displayed. Display only the selected signals in color, unselected signals are...
2020-05-18 rating Views: 968
document
2019-02-25 Device Thesaurus Usage With Database Changes
Question: In a CANape project, the content of the *.dbc file is changed in the following way: the message names have changed, but the signal names are still the same. Now CANape will mark these signals in windows like the Graphics Window as unknown variables. Is it possible to use this new *.dbc...
2019-02-25 rating Views: 686
document
2019-11-08 How to Display Arrays with More Than 16 Elements from Linker-Map-Files
Question: How can I display fields or multi dimensional arrays with more than 16 elements? Answer: In the options dialog of ASAP2 Studio (Backpanel | Options | Linker Map Reader), you can select the Maximum array size, which describes the maximum number of elements that are expanded. The...
2019-11-08 rating Views: 249
document
2020-02-04 How to Convert a DB File into an A2L File
Question: How can I convert a DB file into an A2L file? Answer: These are the steps to convert the DB file into an A2L file: Create a new XCP/CCP CANape device with all necessary configuration steps: Load the DB file as database for the new XCP/CCP device: Import the contents from...
2020-02-04 rating Views: 244
document
2019-04-11 Recording of Modified Calibration Parameters
Question: Why does the MDF file from CANape 16 look different than a MDF file from an earlier CANape version? Answer: Starting with CANape version 16.0, it automatically records modified calibration parameters. If this feature is not desired, e.g. for compatibility reasons, it can be turned...
2019-04-11 rating Views: 240
document
2020-04-17 Accessing Scaling Functions of the Graphics Window With a Script
Question: Is it possible to access the scaling functions of the graphics window (e. g. "fit") with a script? Answer: Yes, this is possible. Here is an example script: double t1, t2; t1 = 10; t2 = 20; // activate diff cursor mode SetGlobalCursorMode(2); // set cursors SetGlobalCursor(t1);...
2020-04-17 rating Views: 239