vector.com|Contact
Search tips

apple banana
Find rows that contain at least one of the two words.

+apple +juice
Find rows that contain both words.

+apple macintosh
Find rows that contain the word 'apple', but rank rows higher if they also contain 'macintosh'.

+apple -macintosh
Find rows that contain the word 'apple' but not 'macintosh'.

+apple ~macintosh
Find rows that contain the word 'apple', but if the row also contains the word 'macintosh', rate it lower than if row does not. This is "softer" than a search for '+apple -macintosh', for which the presence of 'macintosh' causes the row not to be returned at all.

+apple +(>turnover >strudel)
Find rows that contain the words 'apple' and 'turnover', or 'apple' and 'strudel' (in any order), but rank 'apple turnover' higher than 'apple strudel'.

apple*
Find rows that contain words such as 'apple', 'apples', 'applesauce', or 'applet'.

"some words"
Find rows that contain the exact phrase 'some words' (for example, rows that contain 'some words of wisdom' but not "some noise words").

By continuing to use this site you agree to the use of cookies. For more information and to find out how to change this click here. Accept Cookies
Please enable cookies in your browser for this website.
Search:
Advanced search

Test Coverage of the J2602 Slave Conformance Tester

Last updated: 2018-08-13
English Version:

The J2602 Slave Conformance Tester in CANoe implements all test cases from the SAE J2602-2 Conformance Test Specification that concern Slave nodes and can be reasonably implemented by the test system. No Master node test cases are implemented. The basis for the test system are the Vector LIN Interfaces in combination with the VH1150. Using this hardware combination, all ISO/OSI Layer 2 and 3 test cases can be implemented. Some test cases in the specification require a complex electrical setup or additional hardware. Those have to be performed manually or require hardware beyond the LIN interface and the VH1150. The following test cases are not part of the Tester and have to be performed manually:
 

  • 7.7.1.1
  • 7.7.1.2
  • 7.10.1.1
  • 7.10.1.2
  • 7.10.2
  • 7.10.3.1 (7.10.3.2 is implemented)
  • 7.12.3 (should be guaranteed by the transceiver supplier)
     

All other test cases that require additional hardware inform the tester accordingly.
 

Some tests are not meant to be performed by the test system and have to be performed by review, or are application specific and cannot be implemented by the test system:
 

  • 5.6 LIN Product Identification
  • 5.7.1.3 Slave Device Configuration Capabilities
  • 5.7.1.4 Master Configuration Message Pairing
     

A few tests that do not fall into the categories above have not been implemented since they are not relevant enough (e.g. enough Slave nodes actually use these features):
 

  • 5.7.2.3 Slave Configuration Messages
  • 5.7.2.4 Slave Response Messages to Options 2 and 3 in Section 5.7.2.3
     

If you require those tests for your Slave node, please contact us. Additionally, there are some numbering errors in the specification:
 

  • 5.7.4 and 5.7.5 denotes the same test case
  • 7.10.4.3.1 and 7.10.3.2.1 denotes the same test case
     
German Version:
Der J2602 Slave Conformance Tester in CANoe setzt die sinnvoll durch ein Testsystem testbaren Testfälle für LIN Slaves aus der SAE J2602-2 2012 Conformance Test Specification um. Master-Testfälle sind nicht umgesetzt. Basis für die Tests sind die LIN-Interfaces von Vector in Kombination mit dem VH1150. Damit lassen sich alle Tests auf ISO/OSI Schicht 2 und 3 umsetzen. In der Testspezifikation gibt es einige Testfälle, die einen komplexen elektrischen Aufbau benötigen. Diese müssen entweder eigenständig durchgeführt werden oder erfordern zusätzliche Hardware. Eigenständig durchgeführt werden müssen:
 
  • 7.7.1.1
  • 7.7.1.2
  • 7.10.1.1
  • 7.10.1.2
  • 7.10.2
  • 7.10.3.1 (7.10.3.2 ist umgesetzt)
  • 7.12.3 (sollte durch den Transceiver-Hersteller garantiert werden)
     

Diese Tests sind nicht Teil des Conformance Testers.

Bei allen anderen Tests, die besondere elektrische Parameter voraussetzen, wird der Tester entsprechen informiert. Einige Tests sind zudem nicht durch das Testsystem durchzuführen, da sie durch ein Review umgesetzt werden oder applikationsspezifisch sind:
 

  • 5.6 LIN Product Identification
  • 5.7.1.3 Slave Device Configuration Capabilities
  • 5.7.1.4 Master Configuration Message Pairing
     

Einige wenige Tests, die nicht diesen Regeln entsprechen, haben wir zudem nicht umgesetzt, da sie aus unserer Sicht in der Praxis nicht relevant genug sind.

Dies sind: 

  • 5.7.2.3 Slave Configuration Messages
  • 5.7.2.4 Slave Response Messages to Options 2 and 3 in Section 5.7.2.3
     

Bitte teilen Sie uns mit, wenn diese Tests für Ihren J2602-Slave relevant sein sollten. Zusätzlich gibt es Nummerierungsfehler in der Spezifikation:
 

  • 5.7.4 und 5.7.5 sind nur ein Testfall, der zwei Nummern hat
  • 7.10.4.3.1 wird auch als 7.10.3.2.1 geführt
 