vector.com|Contact
Search tips

apple banana
Find rows that contain at least one of the two words.

+apple +juice
Find rows that contain both words.

+apple macintosh
Find rows that contain the word 'apple', but rank rows higher if they also contain 'macintosh'.

+apple -macintosh
Find rows that contain the word 'apple' but not 'macintosh'.

+apple ~macintosh
Find rows that contain the word 'apple', but if the row also contains the word 'macintosh', rate it lower than if row does not. This is "softer" than a search for '+apple -macintosh', for which the presence of 'macintosh' causes the row not to be returned at all.

+apple +(>turnover >strudel)
Find rows that contain the words 'apple' and 'turnover', or 'apple' and 'strudel' (in any order), but rank 'apple turnover' higher than 'apple strudel'.

apple*
Find rows that contain words such as 'apple', 'apples', 'applesauce', or 'applet'.

"some words"
Find rows that contain the exact phrase 'some words' (for example, rows that contain 'some words of wisdom' but not "some noise words").

By continuing to use this site you agree to the use of cookies. For more information and to find out how to change this click here. Accept Cookies
Please enable cookies in your browser for this website.
Search:
Advanced search

VN8900 with CANoe 8.0 – 8.5 Unable to Load CDD

Last updated: 2018-11-30
Issue:

After start of measurement CANoe shows the error message cannot load diagnostic description.

VN8900 stands for VN8910, VN8910A and VN8912 devices.

Solution:

Follow these steps to update the VN8900 and CANoe in order to load the CDD file:

  1. Download the most recent Standalone Manager from the Vector Download Center (do not use the older one delivered with your CANoe version).
     
  2. Install the Standalone Manager.
     
  3. Download the CANoe 9.0 demo environment (*.rtenv file ) from here:
    https://portal.vector.com/shared/c1a0bf0b-97a8-45e2-a1cc-88dafc051584
     
  4. Close all CANoe instances and start the newer Standalone Manager. Select your VN8900:

  5. Select the Execution environment tab. Click update and select the file downloaded previously (*.rtenv file):

    After the successfull installation of this file, power off your VN8900 device.

  6. Switch on your VN8900 device.

  7. Install the persistors on your PC. You can download them from here:

    http://vector.com/persistors

    Select the Converters for CANdelaStudio Diagnostic Descriptions…. and proceed with continue:

  8. Start and connect CANoe, go to Configuration -> Network Hardware and click on Device… and select Update CANoe software. Now your CANoe 8.x is restored to the VN8900.

    After that your CDD(s) should be loaded successfully.
     

Background:

The most recent persistors (CANdela Diagnostic Converters) include the Visual Studio 2013 C++ runtime which is not included on the VN8910 and possibly not on the VN8910A and VN8912 images.
By applying the above procedure this runtime is installed on the device.

If you have CANoe 8.5, a simple update to SP5 on the computer first and then and on the VN8900 is sufficient (see step 8).
 

Note:
For CANoe 9.0 and upper versions please see http://kb.vector.com/entry/903/
 